Warning: implode(): Invalid arguments passed in /www/wwwroot/jobquiz.info/mdiscuss.php on line 336
The maximum area of tension reinforcement in a beam having cross sectional area as’bd’shall not exceed ?->(Show Answer!)
Question Set

1. The maximum area of tension reinforcement in a beam having cross sectional area as’bd’shall not exceed





Ask Your Doubts Here

Type in
(Press Ctrl+g to toggle between English and the chosen language)

Comments

Show Similar Question And Answers
QA->The total number of members in the Legislative Council of a State shall not exceed __ of the total number of members in the State Legislative Assembly.?....
QA->‘We shall either free India or die in the attempt; We shall not live to see the perpetuation of our slavery’ Mahathma Gandhi said these words in connection with?....
QA->How much the time gap between two sessions of the Parliament should not exceed?....
QA->A train of length 150 meters took 8 seconds to cross a bridge of length 250 meters. Time taken by the train to cross a telephone post is....
QA->“The state shall have no religion of its own and all persons shall be equally entilted to freedom of conscience and right freely to profess, practice and propagate religion”- This principle is termed?....
MCQ->The maximum area of tension reinforcement in a beam having cross sectional area as’bd’shall not exceed....
MCQ->Consider the following statements : According to Bandura I. Reinforcement serves as an antecedent rather than a consequent influence II.Reinforcement functions as an informative and motivational operation III.Reinforcement does not function as a mechanical response strengthener IV. Direct reinforcement is not necessary in order for learning to occur. Of the statements :....
MCQ->Consider the following statements with ragard to crack formation and its control: 1. The surface width of the crack should not, in general, exceed 0.30 mm for structures not subjected to aggressive environment. 2. When depth of web in a beam exceeds 750 mm, side face reinforcement @ 0.1 percent of web area should be provided on each face. 3. The nominal spacing of main bars in a slab should not exceed three times the effective depth of a solid slab or 300 mm, whichever is smaller. Which of the statements given above is/are correct ?....
MCQ->The maximum area of tension reinforcement in beams shall not exceed....
MCQ->For double angles carrying tension, placed back to back and connected to either side of the gusset plate, the sectional area of the section, is equal to cross sectional area of....
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions