Toggle navigation
Home
KPSC Previous Question Papers
Article Category
kerala psc
upsc
General
Popular Pages
Multiple Choice Question in engineering-mechanics-kinetics-of-a-particle-impulse-and-momentum
Multiple Choice Question in database-database-redesign
Question Answer in malayalam-kerala-psc-questions
Multiple Choice Question in malayalam-kerala-psc-questions
Multiple Choice Question in current-affairs-2017-03-05
Question Answer in kerala-psc-questions-in-malayalam
Multiple Choice Question in kerala-psc-questions-in-malayalam
Multiple Choice Question in biochemistry-hplc
Multiple Choice Question in electronics-and-communication-engineering-electronic-devices-and-circuits
Multiple Choice Question in database-sql-for-database-construction-and-application-processing
Question Answer in August-2019
Multiple Choice Question in 035/2016
Question Answer Bank
Multiple Choice Question Bank
Question Answer Category
Multiple Choice Question Category
Home
->
Multiple Choice Questions
Question Set
chemical engineering chemical engineering basics
1. In the X-ray radiography technique, the tube voltage for thicker plates as compared to thin plates, should be
(A): higher, as it gives higher wavelength.
(B): higher, as it gives shorter wavelength.
(C): lower, as it gives higher wavelength.
(D): lower, as it gives shorter wavelength.
Previous Question
Show Answer
Next Question
Add Tags
Report Error
Show Marks
Ask Your Doubts Here
Type in
(Press Ctrl+g to toggle between English and the chosen language)
Post reply
Comments
Show Similar Question And Answers
QA->Let a thin capillary tube be replaced with another tube of insufficient length then, we find water?....
QA->The device used for converting current from a lower voltage to a higher voltage is known as?....
QA->Who is the inventor of X-ray tube?....
QA->From which the cathode ray particles originate in a discharge tube?....
QA->The lens thicker at the middle than in edges is called?....
MCQ->In the X-ray radiography technique, the tube voltage for thicker plates as compared to thin plates, should be....
MCQ->A torsion member is fabricated from two concentric thin tubes. At the ends, the tubes are welded to rigid discs so that both the tubes are twisted as a unit. The radius of the outer tube is 2r and that of the inner tube is r. If the shear stresses developed in the outer tube is τ, then the shear stress in the inner tube will be.....
MCQ->S1: Satyajit Ray made several films for children. P : Later film makers have followed his lead. Q : Today other nations are making the children's film in a big way. R : This was at a time when no director considered children as potential audience. S : Ray was, thus, a pioneer in the field. S6: But today few think of Ray as a maker of children's films. The Proper sequence should be:....
MCQ->Tubes are fixed to the tube sheet (a thick circular metallic plate) by the method of tube rolling and brazing (non-removable) or ferrule connection (removable). Thickness of the tube, sheet is normally __________ the outside diameter of the tube but in no case it should be less than 22 mm (7/8").....
MCQ->The target material used in General purpose Radiography x-ray machine is....
×
×
Type The Issue
×
Your Marks
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...
Privacy
|
Terms And Conditions
Question ANSWER With Solution