1. A T-beam behaves as a rectangular beam of a width equal to its flange if its neutral axis





Ask Your Doubts Here

Type in
(Press Ctrl+g to toggle between English and the chosen language)

Comments

Show Similar Question And Answers
QA->The length of a rectangular floor is 2 meters more than its width and its perimeter is 20 meters, then its area is....
QA->A rectangular plot 67 metres long is paved with 2546 tiles each measuring 50 square centimetre. Find the width of the plot ?....
QA->Which is the planet its length of its day and the tilt of its axis are almost identical to those of the earth?....
QA->What is a graph is plotted taking °C along the Y-axis and of K along the X-axis?....
QA->If a graph is plotted taking the temperature in Fahrenheit along the Y-axis and the corresponding temperature in Celsius along X- axis it will be the straight line?....
MCQ->A T-beam behaves as a rectangular beam of a width equal to its flange if its neutral axis....
MCQ->The following quantities refer to a channel section used as a beam : b = width of flange (upto centre of web thickness). h = depth of web (c/c of flange thickness). t = thickness of flange and web. I = moment of inertia of channel about xx axis. e = distance of shear centre, outside the channel from the mid thickness of the web. The value of 'e' is given by....
MCQ->Consider the following statements in respect of plate girders : 1. A large number of cover plates are provided over flange angles so that curtailed flanges match the bending moment diagram exactly. 2. At least one cover plate should extend over the entire span so that rain water may not enter and corrode the connections. 3. A minimum of one-third of flange area should be provided in flange angles and balance in flange cover plates for stability. Which of the statements given above are correct ?....
MCQ->Gross flange area for a riveted plate girder is to be designed considering net area as 80% of its gross area. Consider width of the flange as 500 mm while web plate as 1000 mm x 12 mm. The girder is to resist a maxi-mum BM of 4500 kNm. Maximum allowable bending stress in tension is 150 MPa. Gross flange area is....
MCQ->A singly reinforced beam has breadth b, effective depth d, depth of neutral axis n and critical neutral axis n1. If fc and ft are permissible compressive and tensile stresses, the moment to resistance of the beam, is....
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions
Question ANSWER With Solution