Toggle navigation
Home
KPSC Previous Question Papers
Article Category
kerala psc
upsc
General
Popular Pages
Multiple Choice Question in aptitude-area
Multiple Choice Question in non-verbal-reasoning-grouping-of-images
Multiple Choice Question in aptitude-compound-interest
Multiple Choice Question in engineering-mechanics-kinetics-of-a-particle-impulse-and-momentum
Multiple Choice Question in electronic-devices-bipolar-junction-transistors
Multiple Choice Question in 035/2016
Multiple Choice Question in database-database-redesign
Question Answer in malayalam-kerala-psc-questions
Multiple Choice Question in malayalam-kerala-psc-questions
Multiple Choice Question in current-affairs-2017-03-05
Question Answer in KERALA PSC
Multiple Choice Question in KERALA PSC
Question Answer Bank
Multiple Choice Question Bank
Question Answer Category
Multiple Choice Question Category
Home
->
Multiple Choice Questions
Question Set
civil engineering rcc structures design
1. In a simply supported slab, alternate bars are curtailed at
(A): 1/4th of the span
(B): 1/5th of the span
(C): 1/6th of the span
(D): 1/7th of the span
(E): none of these.
Previous Question
Show Answer
Next Question
Add Tags
Report Error
Show Marks
Ask Your Doubts Here
Type in
(Press Ctrl+g to toggle between English and the chosen language)
Post reply
Comments
Show Similar Question And Answers
QA->“Simply Fly”- ഏത് സ്ഥാപനത്തിന്റെ മുദ്രാവാക്യമാണിത്?....
QA->Which amendment curtailed the power of Judicial review of the Supreme Court and the High Courts?....
QA->In which temple Sree Narayana Guru Installed a slab as idol with the words, “Sathyam’ (Truth), Dharmam (Ethics), Daya (Compassion), Sneham (love)”?....
QA->All type bars rest in the....
QA->The semicircular arrangement of type bars on the segment helps in....
MCQ->In a simply supported slab, alternate bars are curtailed at....
MCQ->In a simply supported slab the minimum spacing of distribution reinforcement, should be four times the effective thickness of the slab or....
MCQ->The pitch of the main bars in a simply supported slab, should not exceed its effective depth by....
MCQ->A fixed beam and a simply supported beam having same span and develop same maximum bending moment due to uniformly distributed load on entire span. What is the ratio of uniformly distributed load on fixed beam to that on simply supported beam ?....
MCQ->Consider the following statements with ragard to crack formation and its control: 1. The surface width of the crack should not, in general, exceed 0.30 mm for structures not subjected to aggressive environment. 2. When depth of web in a beam exceeds 750 mm, side face reinforcement @ 0.1 percent of web area should be provided on each face. 3. The nominal spacing of main bars in a slab should not exceed three times the effective depth of a solid slab or 300 mm, whichever is smaller. Which of the statements given above is/are correct ?....
×
×
Type The Issue
×
Your Marks
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...
Privacy
|
Terms And Conditions
Question ANSWER With Solution