1. The length of a column, having a uniform circular cross-section of 7.5 cm diameter and whose ends are hinged, is 5 m. If the value of E for the material is 2100 tonnes/cm2, the permissible maximum crippling load will be






Ask Your Doubts Here

Type in
(Press Ctrl+g to toggle between English and the chosen language)

Comments

Show Similar Question And Answers
QA->A ship 55 km from the shore springs a leak which admits 2 tonnes of water in 6 minutes, 80 tonnes would suffice to sink her, but the pumps can throw out 12 tonnes an hour. The average rate of sailing that she may just reach the shore as she begins to sink is....
QA->A ship 55 km from the shore springs a leak which admits 2 tonnes of water in 6 minutes, 80 tonnes would suffice to sink her, but the pumps can throw out 12 tonnes an hour. The average rate of sailing that she may just reach the shore as she begins to sink is:....
QA->A train of length 150 meters took 8 seconds to cross a bridge of length 250 meters. Time taken by the train to cross a telephone post is....
QA->A train having a length of 240 metre passes a post in 24 seconds. How long will it take to pass a platform having a length of 650 metre?....
QA->A train moving with uniform speed passed a bridge of length 2000 metres in 2 ½ minutes.It took ½ minutes to pass a telephone post.What is the length of the train in metres?....
MCQ->The length of a column, having a uniform circular cross-section of 7.5 cm diameter and whose ends are hinged, is 5 m. If the value of E for the material is 2100 tonnes/cm2, the permissible maximum crippling load will be....
MCQ->The equivalent length, of a given column with given end conditions, is the length of an equivalent column of the same material and cross-section with hinged ends, and having the value of crippling load equal to that of the given column.....
MCQ->According to Euler's column theory, the crippling load for a column of length (l) fixed at both ends is __________ the crippling load for a similar column hinged at both ends.....
MCQ->According to Euler's column theory, the crippling load for a column of length (l) with one end fixed and the other end free is __________ the crippling load for a similar column hinged at both the ends.....
MCQ->A short column 20 cm x 20 cm in section is reinforced with 4 bars whose area of cross section is 20 sq. cm. If permissible compressive stresses in concrete and steel are 40 kg/cm2 and 300 kg/cm2, the Safe load on the column, should not exceed....
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions
Question ANSWER With Solution