1. A single phase half wave converter is used to charge a battery of 50 V. The thyristor is continuously fired by dc signal. Input voltage is v = Vm sin ωt. The thyristor will conduct
Ask Your Doubts Here
Comments
By: guest on 02 Jun 2017 01.11 am
Thyristor can conduct only when it is forward biased. This occurs only when v > 50 V.