Warning: implode(): Invalid arguments passed in /www/wwwroot/jobquiz.info/mdiscuss.php on line 336
The minimum area of tension reinforcement required in a rectangular beam section 200 mm cr 400 mm if Fe415 steel is used at 25 mm effective cover: ?->(Show Answer!)
Question Set

1. The minimum area of tension reinforcement required in a rectangular beam section 200 mm cr 400 mm if Fe415 steel is used at 25 mm effective cover:





Ask Your Doubts Here

Type in
(Press Ctrl+g to toggle between English and the chosen language)

Comments

Show Similar Question And Answers
QA->A steel wire when bent in the form of a square encloses an area of 121 sq. cm. If the same wire is bent into the form of a circle, the area of the circle is—....
QA->The length and breadth of a rectangular field in the ratio of 12: 7 . Find the length if area of the field is 52,500 Sq.m?....
QA->The area of a rectangular plot is 460460 square metres. If the length is 15%15% more than the breadth, what is the breadth of the plot?....
QA->The length of a rectangular floor is 2 meters more than its width and its perimeter is 20 meters, then its area is....
QA->Stainless Steel ഉണ്ടാക്കാൻ Steel ൻ്റെകുടെ ചേർക്കുന്ന ലോഹം....
MCQ->The minimum area of tension reinforcement required in a rectangular beam section 200 mm cr 400 mm if Fe415 steel is used at 25 mm effective cover:....
MCQ->Consider the following statements : According to Bandura I. Reinforcement serves as an antecedent rather than a consequent influence II.Reinforcement functions as an informative and motivational operation III.Reinforcement does not function as a mechanical response strengthener IV. Direct reinforcement is not necessary in order for learning to occur. Of the statements :....
MCQ->If the main reinforcement of the slab is parallel to a T-beam, the transverse reinforcement at mid span of the slab is provided at least ......of main reinforcement....
MCQ->Consider the following statements in respect of plate girders : 1. A large number of cover plates are provided over flange angles so that curtailed flanges match the bending moment diagram exactly. 2. At least one cover plate should extend over the entire span so that rain water may not enter and corrode the connections. 3. A minimum of one-third of flange area should be provided in flange angles and balance in flange cover plates for stability. Which of the statements given above are correct ?....
MCQ->Consider the following statements regarding the working stress design of under-reinforced RC sections: 1. The neutral axis depth will be greater than that of a balanced section 2. The stress in steel in tension will reach its maximum permissible value first 3. The moment of resistance will be less than that of the balanced section 4. The concrete on'the tension side is also to be considered for calculating the moment of resistance of the section. Of these statement :....
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions
Question ANSWER With Solution