1. In actual air-conditioning applications for R-12 and R-22, and operating at a condenser temperature of 40° C and an evaporator temperature of 5° C, the heat rejection factor is about





Ask Your Doubts Here

Type in
(Press Ctrl+g to toggle between English and the chosen language)

Comments

Show Similar Question And Answers
QA->Who is the inventor of Air Conditioning?....
QA->Most fish do not sink in water because of the presence of: swim bladder; air bladder; air sacs; air in spongy bones?....
QA->What is the amount of actual water vapour of air?....
QA->The main function of the ignition condenser is:....
QA->Which factor is not needed to calculate heat lost or gain when there is no change of state?....
MCQ->In actual air-conditioning applications for R-12 and R-22, and operating at a condenser temperature of 40° C and an evaporator temperature of 5° C, the heat rejection factor is about....
MCQ->A Windows 2000 Server computer named server2 runs numerous 32bit applications and two 16bit applications. Users start the 16bit applications by running APP1.EXE for one application and APP2.EXE for another application. The 16bit applications are configured to run in the separate memory space. You want to create a performance base like chart in the system monitor for all the applications on server2. You add all of 32bit applications and now you want to add two 16bit applications. What should you do?....
MCQ->It is desired to concentrate a 20% salt solution (20 kg of salt in 100 kg of solution) to a 30% salt solution in an evaporator. Consider a feed of 300 kg/min at 30°C. The boiling point of the solution is 110°C, the latent heat of vaporisation is 2100 kJ/kg and the specific heat of the solution is 4 kJ/kg.K. The rate at which the heat has to be supplied in (kJ/min) to the evaporator is....
MCQ->The inner wall of a furnace is at a temperature of 700°C. The composite wall is made of two substances, 10 and 20 cm thick with thermal conductivities of 0.05 and 0.1 W.m-1.°C-1 respectively. The ambient air is at 30°C and the heat transfer co-efficient between the outer surface of wall and air is 20 W.m-2.°C-1. The rate of heat loss from the outer surface in W.m-2is....
MCQ->1000 Kg of liquid at 30°C in a well stirred vessel has to be heated to 120°C, using immersed coils carrying condensing steam at 150°C. The area of the steam coils is 1.2 m2 and the overall heat transfer co-efficient to the liquid is 1500 W/m2.°C. Assuming negligible heat loss to the surrounding and specific heat capacity of the liquid to be 4 kJ/kg.°C, the time taken for the liquid to reach desired temperature will be....
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use | Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions
Question ANSWER With Solution