1. In a single phase full wave converter (M - 2 connection) feeding a highly inductive load, the firing angle for each thyristor is a in the respective half cycle. The period of conduction of each thyristor is
Ask Your Doubts Here
Comments
By: guest on 02 Jun 2017 01.10 am
Since conduction is from a to p + a , period of conduction is p in each half cycle.